Stereoscopic library Fire code requirements are a series of regulations established to ensure the safety of goods stored in the three-dimensional warehouse and reduce the risk of fire. The following are the requirements of several common fire codes for stereoscopic warehouses:
1. Supporting fire-fighting facilities: The stereo warehouse shall be equipped with appropriate fire-fighting facilities, including fire extinguishers, automatic sprinkler systems, smoke detectors, fire alarm systems, etc., to ensure that timely measures can be taken to extinguish or evacuate in case of a fire.
2. Fire separation: The stereoscopic warehouse shall have clear fire separation requirements to separate different areas and reduce the risk of fire spread. This can be achieved by setting fire walls, fire doors and other measures to prevent the spread of flame and smoke between different areas.
3. Fire alarm system: The stereo warehouse shall be equipped with a reliable fire alarm system, so that in case of fire, the equipment can send out sound or light signals in time to warn the staff to take corresponding countermeasures.
4. Emergency passageway and evacuation passageway: There should be enough emergency passageways and evacuation passageways with width in the stereoscopic warehouse, so that in case of fire or other emergencies, people can quickly and safely evacuate.
5. Fire and explosion prevention of transport vehicles: the stereo warehouse also has some requirements for transport vehicles entering the warehouse area, such as requiring transport vehicles to be modified according to fire and explosion prevention requirements to reduce the occurrence and spread of fire.
6. Storage restrictions: The stereoscopic warehouse shall formulate restrictions on storage and prohibit the storage of flammable, explosive, toxic, radioactive and other dangerous goods to reduce the risk of fire occurrence and spread.
7. Inspection and maintenance of fire-fighting equipment: regularly inspect and maintain the fire-fighting equipment in the stereo warehouse to ensure its normal operation and effectiveness. For example, regularly check the inflation pressure of the fire extinguisher and the water pressure of the fire water system.
The above are some common fire code requirements for stereoscopic warehouses. These requirements are intended to ensure the safety of goods and staff stored in the stereoscopic warehouses. Specific requirements may vary depending on the nature of countries, regions and stereoscopic libraries. Therefore, it is recommended to refer to the relevant local fire regulations and standards when designing and operating the stereoscopic warehouse to ensure compliance with the specification requirements and provide safety assurance.